TCHP 17

This versatile unit, capable of delivering 17kW, and can serve as a heat pump, a reversible heat pump, a chiller, or even a domestic hot water heat pump. Its unique design allows for simultaneous heating and cooling if you utilize both sides. It can handle up to 50°C return temperature out of the box or up to 60°C if you use our hydronic kit. It can be delivered both with and without casing, and can be made reversible with the reversing kit.

Get in touch

Allows for simultaneous, numerous variable temperatures

Enables heat recovery from countless sources

Hydronic kit with plug-and-play functionality

Pre-configured for plug-and-play-functionaloity

Return temperature up to 60°C with our hydronic kit

Simultaneous heating and cooling capabilities

Specifications

Refrigerant

CO₂

Compressor

Bitzer 4PTE-7K

Capacity control

CRII: 10-100%

Chilled water

+15°C til -15°C

Hot water

+20°C - +90°C

Highest possible return temp*

60°C

Cooling

18kW

Heating

17kW

COP Heating

3,3 - 5,42

COP Cooling (chilled water 12/7)

3 - 4,57

COP Domestic hot water (return cold side 10°C)

4,32

COP during heat recovery

7,2 - 8,7

Domestic hot water per minute (70°C)

4 l/min

Fuse size

40A

Voltage

400V

Dimensions

LxBxH: 1462 x 690 x 1913mm

Water connection dimensions

28mm

Capacities and dimensions

Refrigerant

CO₂

Compressor

Bitzer 4PTE-7K

Capacity control

CRII: 10-100%

Chilled water

+15°C til -15°C

Hot water

+20°C - +90°C

Highest possible return temp*

60°C

Cooling

18kW

Heating

17kW

COP Heating

3,3 - 5,42

COP Cooling (chilled water 12/7)

3 - 4,57

COP Domestic hot water (return cold side 10°C)

4,32

COP during heat recovery

7,2 - 8,7

Domestic hot water per minute (70°C)

4 l/min

Fuse size

40A

Voltage

400V

Dimensions

LxBxH: 1462 x 690 x 1913mm

Water connection dimensions

28mm

LxWxH: 1462 x 690 x 1913mm

5.0
COP Heat
4.4
COP Cool
90°C
Water Temp
1
GWP
Tequs Offshore

Tequs Offshore

Tequs Offshore is custom-designed CO2 machines ideally suited for offshore applications.

Tequs Offshore
Consulting

Project development and commissioning consulting

We at Tequs have a competent team and resources with extensive experience in the development of projects within refrigeration.

Project development and commissioning consulting
Commissioning

Pre-configuration and Startup packages

Are you aiming to reduce installation time? We can do the start up in our laboratory or out on site. If you need assistance with the startup or want us to pre-configure the unit, we can help you with this.

Pre-configuration and Startup packages
Hydronic kits

Tequs Flow

The entire water side in a box. We offer both standardized hydromodules and customized modules. It enables return temperatures up to 60°C. It allows for the provision of heating and cooling at multiple temperature levels simultaneously. 

Tequs Flow
Tequs Offshore

Tequs Offshore

Tequs Offshore is custom-designed CO2 machines ideally suited for offshore applications.

Consulting

Project development and commissioning consulting

We at Tequs have a competent team and resources with extensive experience in the development of projects within refrigeration.

Commissioning

Pre-configuration and Startup packages

Are you aiming to reduce installation time? We can do the start up in our laboratory or out on site. If you need assistance with the startup or want us to pre-configure the unit, we can help you with this.

Hydronic kits

Tequs Flow

The entire water side in a box. We offer both standardized hydromodules and customized modules. It enables return temperatures up to 60°C. It allows for the provision of heating and cooling at multiple temperature levels simultaneously. 

FAQ

What is a CO₂ Heat Pump?

All heat pumps and cooling systems (chillers) use a working fluid (refrigerant). Most heat pumps and chillers use synthetic refrigerants that either contribute to global warming or contain substantial amounts of PFAS, which are considered a serious health hazard. A CO₂ Heat Pump or chiller is a unit that uses carbon dioxide (CO₂) as its working fluid, which does not contribute to global warming or the release of chemicals.

Doesn't CO₂ contribute to global warming?

R744 (CO2) is recycled from various industrial processes and does not contribute to the release of new CO2 into the atmosphere and is therefore not contributing to global warming or release of chemicals. It is said that CO2 has a Global Warming Potential (GWP) of 1. One could argue that CO2 as a refrigerant actually has a GWP of 0, as it removes CO2 from the atmosphere when a CO2 system is filled. However, since the gas is eventually released back into the atmosphere at some point in the future, we have chosen to use the conservative figure: GWP=1.

Are CO₂ heat pumps better than other heat pumps?

In the most applications, a good CO2 heat pump is in a class of its own. The reason for this is that it can heat liquid to much higher temperatures than other refrigerants can. This increases energy efficiency, as other heat pumps need assistance from a fossil or electric heat source to heat the liquid all the way to the desired temperature. If you utilize this advantage on both the cold and hot side of the heat pump, for example, you can get free domestic hot water at a hotel in the summer when delivering cold water for comfort cooling. In such cases, you can achieve a COP (Coefficient of Performance) as high as 8-9. This means that for every kW of electricity used, you get 8-9 kW out.

What are the applications of Tequs heat pumps?

You can be creative. Our products are extremely flexible and can be used for both heating and cooling at the same time. The heat pumps and chillers cover a heating and/or cooling requirement from 17kW (1*TCHP17) up to 804kW (3*TCHP268). Typical projects where our units are delivered include hotels, office buildings, residential complexes, swimming pools, and for industrial cooling needs such as data centers, food production, etc.

Isn't it very demanding to install CO₂ heat pumps?

Traditional CO2 heat pumps are demanding to install and require a very high level of competence and experience. You must be able to lay high-pressure gas pipes and have experience with the commissioning of complex systems. A heat pump from Tequs is plug and play. You only need plumbing expertise as it only needs to be connected with liquid and electricity

Aren't CO₂ heat pumps less efficient at high return temperatures?

Traditionally, CO2 heat pumps have been less efficient at high return temperatures. Our heat pumps use ejector technology that utilizes the high pressure and temperature to maintain efficiency. This means that our heat pumps are not only more efficient than traditional heat pumps, but they are also very suitable for high-temperature systems.

How do you handle returntemperatures higher than 37°C?

By using an ejector, the heat pump alone can handle a return temperature of 42°C. In combination with our hydronic kit, it can handle return temperatures up to 60°C.

Contact us for more information

Thank you! Your submission has been received!